KXM2LE series residual current protected moulded case circuit breaker
Summarization:
KXM2LE series residual current protected circuit breaker, its rated isolating voltage is 800V, apply to circuit with AC50Hz, rated working voltage 400V, rated current till 800A for infrequent conversion and electric motor infrequent start. Circuit breaker have overload, short circuit and under voltage protection function, can protect circuit and power supply apparatus from being damaged, meanwhile, can provide indirect contact protection to human, also can provide over current protection to non-detectable but long existed ground fault which may have fire risk. Rated residual operation current 30mA circuit breaker have additional protection function to direct contact person while other protection apparatus have fault.
◎Circuit breaker have small volume, high breaking capacity, short arc, anti-shake etc features.
◎Circuit breaker can be installed vertically or horizontally
◎This product according to below criteria:
IEC60947-1 and GB14048.1-2006
IEC60947-2 and GB14048.1-2008
◎Circuit breaker suitable for isolating , express code is " "
Normal working and installation criteria:
◎Surrounding media temperature can't higher than +40℃ or lower than -5℃; and average temperature in 24 hours can't exceed 35℃(except special ordering)
◎Installation place relative humidity can't exceed 50% while max temperature is +40℃,higher relative humidity is acceptable in lower temperature, for example relative humidity can reach 90% at 20℃,should adopt special measure when have condensation dewdrop which caused by temperature changing.
◎Humid tropical type circuit breaker relative humidity can't exceed 95% at +25℃;
◎Pollution degree: III
◎Main circuit of circuit breaker installation type is III, auxiliary circuit and control circuit (non connect to main circuit) installation type is II
◎Circuit breaker apply to electric magnetic surrounding A
◎Humid tropical circuit breaker can resist humid tropical, smoke, mycete affect.
◎Circuit breaker should install in the place without explosion risk, without conducting dust, unable metal corrosive and non-damage isolator
◎Installation place can't hit by rain, snow directly
◎Circuit breaker should install according to instruction.
KXM2LE Model No. and meaning: (see bottom attachment)
Main features:
◎Residual current three phases protection:KXM2LE circuit breaker realize ground fault protection, residual current protection module working power supply of regular residual current protection circuit breaker is 2 phases, this series circuit breaker is 3 phases, the module still can work normally if lack any of the phases.
◎Can be adjustable in installation place: rated residual operation current I△n and residual current operation time(non delay and delay) can be adjusted according to place condition.
◎Low voltage protection: residual current protection module can work normally even single phase reduce to 85V
◎Residual current output alarm function: Apparatus or circuit residual current reach or exceed setting parameter, circuit breaker with residual current unit module output one electrical independent contact signal to drive relative alarm device.
◎Interconvertible installation: overall specification is as same as M1 series circuit breaker(except M1-630)
Main technical parameter:
KXM2LE-100 | KXM2LE-225 | KXM2LE-400 | KXM2LE-630,800 | ||||||||||
Moulded case current (Inm)(A) | 100 | 225 | 400 | 630,800 | |||||||||
Rated current (In)(A) | (10),16,20,25,32 | 100,125,140,160 | 225,250,315 | 455,500,630 | |||||||||
40,50,63,80,100 | 180,200,225 | 350,400 | 700,800 | ||||||||||
Pole | 2 | 3 | 4 | 2 | 3 | 4 | 3 | 4 | 3 | 4 | |||
Rated isolation voltage (Ui)(V) | AC800 | ||||||||||||
Rated working voltage (Ue)(V) | AC400 | ||||||||||||
Rated impulse withstand voltage (Uimp) (V) | 8000 | ||||||||||||
Arc distance | 50 | 100 | |||||||||||
Breaking capacity degree | L | M | L | M | M | M | |||||||
Limit short circuit breaking capacity (Icu) (kA) | AC400V | 35 | 50 | 35 | 50 | 65 | 65 | ||||||
Running short circuit breaking capacity (Ics) (kA) | AC400V | 22 | 35 | 22 | 35 | 42 | 42 | ||||||
Rated residual short circuit connect (breaking) capacity (I△m) (kA) | 1/4Icu | ||||||||||||
Rated residual operation current (I△n)(mA) | Non delay type | 30/100/500, 100/300/500 | 30/100/500, 100/300/500 | 100/300/500 | 300/500/1000 | ||||||||
Delay type | 100/300/500 | 100/300/500 | 100/300/500 | 300/500/1000 | |||||||||
Rated residual non-operation current (I△no)(mA) | 1/2 I△n | 1/2 I△n | 1/2 I△n | 1/2 I△n | |||||||||
Operation performance (times) | Power on | 1500 | 1000 | 1000 | 1000 | ||||||||
Power off | 8500 | 7000 | 4000 | 4000 | |||||||||
Total times | 10000 | 8000 | 5000 | 5000 | |||||||||
Residual current protection action time | I△n | 2 I△n | 5 I△n | 10 I△n | |||||||||
Max breaking capacity time(s) | Non delay type | 0.3 | 0.15 | 0.04 | 0.04 | ||||||||
Delay type | 0.4/1
| 0.4/1 | 0.4/1 | 0.4/1 | |||||||||
Note:
1. When this series3 pole circuit breaker connect three phases and load, load should without neutral line, load control circuit power supply of circuit breaker load terminal also should without neutral line, otherwise will cause fault operation.
2. When this series 3poles and 4 poles circuit breaker connect single phases and load, phase line should connect A pole, neutral line should connect C pole, can't connect B pole.
Surrounding temperature changing derating factor:
Temperature Model No. | +30℃ (Vessel use +45℃) | +40℃
| +45℃ | +50℃ | +55℃ | +60℃ |
Derating factor
| Derating factor
| Derating factor
| Derating factor
| Derating factor
| Derating factor
| |
KXM2LE-100 | 1In | 0.95In | 0.89In | 0.84In | 0.76In | 0.66In |
KXM2LE-225 | 1In | 0.95In | 0.9In | 0.86In | 0.82In | 0.74In |
KXM2LE-400 | 1In | 0.94In | 0.87In | 0.81In | 0.73In | 0.65In |
KXM2LE-630,800 | 1In | 0.93In | 0.83In | 0.83In | 0.76In | 0.68In |
Note: Above derating factor be tested under moulded case rated current |
High altitude derating factor:
Altitude(m) | 2000 | 3000 | 4000 | 5000 |
Power frequency withstand voltage(V) | 3000 | 2500 | 2000 | 1800 |
Working current correction factor | 1 | 0.94 | 0.88 | 0.83 |
Short circuit breaking capacity correction factor | 1 | 0.83 | 0.71 | 0.63 |
Protection feature:
◎For distribution protection
Tripping mechanism rated current(A) | Thermal tripping mechanism(surrounding temperature +30℃) | Electromagnetic tripping operation current(A) | ||
1.05In(cold) non operation in time | 1.3In(hot) operation in time | |||
10≤In≤63 | Non operation in 1h | operation in 1h | 10In±20% | |
63﹤In≤140 | Non operation in 2h | operation in 2h | ||
140﹤In≤800 | Non operation in 2h | operation in 2h | 5In±20% | 10In±20% |
◎For electric motor protection
Tripping mechanism rated current(A) | Thermal tripping mechanism(surrounding temperature +30℃) | Electromagnetic tripping operation current(A) | ||||
1.05In(cold) non operation in time | 1.2In(hot) operation in time | 1.5In(hot) operation in time | 1In(cold) non operation in time | Tripping degree | ||
10≤In≤800 | Non operation in 2h | operation in 2h | operation in 8min | 6s﹤Tp≤20s | 20 | 12In±20% |
Circuit breaker distribution protection characteristic curve:
◎KXM2LE-100L,M time/current characteristic curve(distribution)
◎KXM2LE-225L,M time/current characteristic curve(distribution)
◎KXM2LE-400M time/current characteristic curve(distribution)
◎KXM2LE-630M,800m time/current characteristic curve(distribution)
Circuit breaker electric motor protection characteristic curve:
◎KXM2LE-100L,M time/current characteristic curve(electric motor)
◎KXM2LE-225L,M time/current characteristic curve(electric motor)
◎KXM2LE-400M time/current characteristic curve(electric motor)
◎KXM2LE-630M,800m time/current characteristic curve(electric motor)
Overall and installation size
◎Front panel wire connecting overall and installation size
Model NO. | Pole | Overall size(mm) | Installation size(mm) | |||||
L1 | L2 | L3 | L4 | a | b | d | ||
KXM2LE-100L | 3 | 92max | 150max | 94max | 75max | 30 | 129 | Φ4.5 |
4 | 122max | 150max | 94max | 75max | 60 | 129 | Φ4.5 | |
KXM2LE-100M | 2 | 62max | 150max | 110max | 92max | - | 129 | Φ4.5 |
3 | 92max | 150max | 110max | 92max | 30 | 129 | Φ4.5 | |
4 | 122max | 150max | 110max | 92max | 60 | 129 | Φ4.5 | |
KXM2LE-225L | 3 | 107max | 165max | 94max | 72max | 35 | 126 | Φ4.5 |
4 | 142max | 165max | 94max | 72max | 70 | 126 | Φ4.5 | |
KXM2LE-225M | 3 | 107max | 165max | 110max | 90max | 35 | 126 | Φ4.5 |
4 | 142max | 165max | 110max | 90max | 70 | 126 | Φ4.5 | |
KXM2LE-400M | 3 | 150max | 257max | 146max | 106max | 44 | 194 | Φ7 |
4 | 198max | 257max | 146max | 106max | 44 | 194 | Φ7 | |
KXM2LE-630M KXM2LE-800M | 3 | 210max | 280max | 155max | 116max | 70 | 243 | Φ7 |
4 | 280max | 280max | 155max | 116max | 70 | 243 | Φ7 |
Note: Back panel wire connecting, plug in type overall and installation, hole boring size, according to accessory supplier's size, this series accessory size only for reference.
◎Back panel wire connecting overall and installation size
Model No. | Overall size(mm) Installation size | ||||||||||
L1 | L2 | L3 | H1 | H2 | A1 | A2 | b1 | b2 | D | d | |
KXM2LE-100 | 164 | 132 | 35 | 53 | 93 | 72 | 102 | 90 | 132 | Φ22 | Φ5.5 |
KXM2LE-225 | 173 | 144 | 35 | 55 | 100 | 87 | 122 | 93 | 144 | Φ24 | Φ5.5 |
KXM2LE-400 | 267 | 224 | 37 | 48.5 | 108.5 | 124 | 172 | 164 | 224 | Φ32 | Φ6.5 |
KXM2LE-630 | 295 | 243 | 37 | 62 | 84 | 178 | 248 | 158 | 243 | Φ48 | Φ7.0 |
KXM2LE-800 | 295 | 243 | 37 | 62 | 84 | 178 | 248 | 158 | 243 | Φ48 | Φ7.0 |
◎Plug in type back panel wire connecting overall and installation size
Model No. | W1 | W2 | L | L1 | L2 | A | H1 | H2 | H3 | A1 | A2 | B | d |
3P | 4P | 3P | 4P | ||||||||||
KXM2LE-100 | 84 | 115 | 168 | 132 | 90 | 31 | 17.5 | 50 | 64 | 60 | 90 | 56 | Φ6.5 |
KXM2LE-225 | 100 | 135 | 183 | 144 | 88 | 41 | 17.5 | 50 | 71.5 | 70 | 105 | 54 | Φ6.5 |
KXM2LE-400 | 142 | 190 | 279 | 224 | 166 | 48 | 21 | 60 | 83.5 | 60 | 108 | 129 | Φ8.5 |
KXM2LE-630 | 203 | 273 | 196 | 243 | 183 | 48 | 18 | 61 | 97 | 140 | 210 | 143 | Φ10 |
KXM2LE-800 | 203 | 273 | 196 | 243 | 183 | 48 | 18 | 61 | 97 | 140 | 210 | 143 | Φ10 |
Note: Back panel wire connecting, plug in type overall and installation, hole boring size, according to accessory supplier's size, this series accessory size only for reference.