KXM2LE residual current operated circuit breaker series accessory 

Price: 0.1~50.0 USD 
Payment Terms: T/T,L/C,WU 
Place of Origin: Zhejiang, China (Mainland) 
inquire skype
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: KXM2LE 100-800 accessory
Production Capacity: 100000PCS/PER MONTH
Delivery Date: 30 days or customized
Poles Number: 4
Frequence: AC50Hz
Application: modern construction
Criteria: GB10963.1-2005
Rated breaking capacity:: 10000
Accessories: SD,OF,MX,MX+OFF,MV,MN,MV+MN...
Means of Transport: Ocean,Land,Air
Packing: Neutral or customized
Type: Moulded Case
Brand Name: CHKX
Rated working voltage: 400V or lower
Breaking capacity: 100kA
Pole: 2,3,4
Rated Isolating voltage: 690V
Rated current: 63A,100A,225A,400A,630A,800...

apply to circuit with AC50Hz, rated working voltage 400V, rated current till 800A for infrequent conversion and electric motor infrequent start.

Summarization:

KXM2LE series residual current protected circuit breaker, its rated isolating voltage is 800V, apply to circuit with AC50Hz, rated working voltage 400V, rated current till 800A for infrequent conversion and electric motor infrequent start. Circuit breaker have overload, short circuit and under voltage protection function, can protect circuit and power supply apparatus from being damaged, meanwhile, can provide indirect contact protection to human, also can provide over current protection to non-detectable but long existed ground fault which may have fire risk. Rated residual operation current 30mA circuit breaker have additional protection function to direct contact person while other protection apparatus have fault.

◎Circuit breaker have small volume, high breaking capacity, short arc, anti-shake etc features.

◎Circuit breaker can be installed vertically or horizontally

◎This product according to below criteria:

IEC60947-1 and GB14048.1-2006

IEC60947-2 and GB14048.1-2008

◎Circuit breaker suitable for isolating , express code is " "

Normal working and installation criteria:

◎Surrounding media temperature can't higher than +40℃ or lower than -5℃; and average temperature in 24 hours can't exceed 35℃(except special ordering)

◎Installation place relative humidity can't exceed 50% while max temperature is +40℃,higher relative humidity is acceptable in lower temperature, for example relative humidity can reach 90% at 20℃,should adopt special measure when have condensation dewdrop which caused by temperature changing.

◎Humid tropical type circuit breaker relative humidity can't exceed 95% at +25℃;

◎Pollution degree: III

◎Main circuit of circuit breaker installation type is III, auxiliary circuit and control circuit (non connect to main circuit) installation type is II

◎Circuit breaker apply to electric magnetic surrounding A

◎Humid tropical circuit breaker can resist humid tropical, smoke, mycete affect.

◎Circuit breaker should install in the place without explosion risk, without conducting dust, unable metal corrosive and non-damage isolator

◎Installation place can't hit by rain, snow directly

◎Circuit breaker should install according to instruction.

Accessory

◎Inner accessory:

According to user's demand circuit breaker can lead wire directly(wire length is 1250px, special request should be informed when ordering), or install additional wire terminal.

Shunt trip mechanism (MX)

KXM2LE residual current operated circuit breaker series accessory

Rated control power supply voltage (Us)(V)

AC230V,AC400V; DC24V,DC110V,DC220V

Operation voltage(V)

(0.7-1.1)Us

Wire connecting drawing

KXM2LE residual current operated circuit breaker series accessory

Note: K-shunt trip mechanism inner microswitch which connect in series with coil is a normally closed contact, this contact disconnect when circuit breaker switch off. In the  dashed box is circuit breaker inner accessory wire connecting drawing.

 

Note: when rated control power supply voltage is DC24V, have 2 solutions:

Solution 1:Adopt DC24V shunt trip mechanism, but should according to below criteria: copper wire max length(both wire length) should according to below table, trip mechanism wire connecting terminal power supply power minimum need 50W

Wire section area

1.5mm2

2.5mm2

Rated control power supply voltage(Us)(DC24V)

100 Us

150m

250m

85% Us

100m

160m

Solution 2:Adopt 24V middle relay control AC230V or 400V shunt trip mechanism, middle relay contact volume should not less than 1A.

 

Undervoltage trip mechanism

(MN)

KXM2LE residual current operated circuit breaker series accessory

 

Rated control power supply voltage (Us)(V)

AC230V,AC400V;

Operation voltage(V)

If voltage is 35%-70% of the rated working voltage, it will make circuit breaker trip reliably;  If voltage is 80% of the rated working voltage, should ensure circuit breaker switch on; if voltage lower than 35% of the rated working voltage should prevent switch on.

Wire connecting drawing

KXM2LE residual current operated circuit breaker series accessory

Note: X- wire connecting terminal row, in the  dashed box is circuit breaker inner accessory wire connecting drawing.

 Warn: Undervoltage trip mechanism need power on firstly, then circuit breaker can be switch ON/OFF, otherwise circuit breaker will be destroyed.

 

Auxiliary contact (OF)

KXM2LE residual current operated circuit breaker series accessory

Conventional thermal current (Ith)(A)

3A

Rated working current (Ie)(A)

AC400: when Inm ≤400A is 0.3A;when 630≤Inm≤800A is 0.4A; when 100A≤Inm≤800A is 0.15A

Wire connecting drawing

KXM2LE residual current operated circuit breaker series accessory

Circuit breaker in trip-free or "OFF" position condition

KXM2LE residual current operated circuit breaker series accessory

Circuit breaker in "ON" position condition

 

Alarm contact (SD)

KXM2LE residual current operated circuit breaker series accessory

Conventional thermal current (Ith)(A)

3A

Rated working current (Ie)(A)

When AC400V is 0.3A; when DC220V is 0.15A

Wire connecting drawing

KXM2LE residual current operated circuit breaker series accessory

Circuit breaker in "ON" "OFF" position condition

KXM2LE residual current operated circuit breaker series accessory

Circuit breaker in trip-free (Alarm) position condition

 

Alarm module

KXM2LE residual current operated circuit breaker series accessory

Input voltage(V)

AC23V,AC400V

Wire connecting drawing

KXM2LE residual current operated circuit breaker series accessory

Explanation:

P5-P6: power supply input

P3-P4: normally open; contact, contact volume AC230V,5A;

P1-P2:Normally close contact, contact volume AC230v,5A;

Note: in the  dashed box is circuit breaker inner accessory wire connecting drawing.

Note: Leakage current alarm module have 2 working way, user can order according your own request:

I:When electricity leaking, current leakage module send alarm signal, and circuit breaker trip simultaneously.

II: When electricity leaking, current leakage module send alarm signal, but circuit breaker not trip.

(II is for special place, user need deliberation when you adopt this function)

◎Outer accessory:

 

 

 

 

Electric operation mechanism

 

KXM2LE residual current operated circuit breaker series accessory

 

 

 

 

 

 

 

Input voltage(V)

AC230V,AC400V; DC110V,DC230V,DC24V

Wire connecting drawing

 

Explanation: P1-P2: Connect with power supply input;

SB1,SB2: operation button(provide by userself )

Note: in the  dashed box is circuit breaker inner accessory wire connecting drawing.

Note: Electric operation mechanism should re-close after circuit breaker tripping.  

KXM2LE residual current operated circuit breaker series accessory  KXM2LE residual current operated circuit breaker series accessory

Matched model No.

Electric operation mechanism parameter

Overall size(mm)

Installation size(mm)

Operation current (A)

Motor power (VA)

Mechanical life (times)

H

a

b

KXM2LE-100

≤0.5A

14

20000

89.5

30

129

KXM2LE-225

≤0.5A

14

20000

93

35

126

KXM2LE-400

≤2A

35

10000

142

44

215

KXM2LE-630

≤2A

35

10000

146

70

243

KXM2LE-800

≤2A

35

10000

146

70

243

 

Handle operation mechanism

KXM2LE residual current operated circuit breaker series accessory

KXM2LE residual current operated circuit breaker series accessory

Model No.

KXM2LE-100

KXM2LE-225

KXM2LE-400

KXM2LE-630

KXM2LE-800

Installation size (H) (mm)

49

55

74

66

66

Note: Back panel wire connecting, plug in type overall and installation, hole boring size, according to accessory supplier's size, this series accessory size only for reference.

 

 

bigPhoto
skype Ms. RUBY XIA

Tel: 86-531-88626363
Fax: 86-531-88626268
Mobile: 135 1577 0044
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

JINAN STAR ELECTRIC EQUIPMENT CO., LTD [China (Mainland)]


Business Type:Manufacturer, Trading Company, Agent
City: Wenzhou
Province/State: Zhejiang
Country/Region: China (Mainland)

RUBY XIA:   skype
RUBY:   qq

You May Like: