Post Offer Free
JINAN STAR ELECTRIC EQUIPMENT CO., LTD
JINAN STAR ELECTRIC EQUIPMENT CO., LTD  

Gold Index: 10362

You are here: home  > Circuit breaker  > KXQ1 dual power automatic transfer switch series

KXQ1 dual power automatic transfer switch series 

Price: 0.1~50.0 USD 
Payment Terms: T/T,L/C,WU 
Place of Origin: Zhejiang, China (Mainland) 
inquire skype
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: KXQ1-63/3/4
Production Capacity: 100000PCS/PER MONTH
Delivery Date: 30 days or customized
Poles Number: 3
single chip: low power consumption
Used in: dual power supply system
Pole: 3,4
apparatus type: CB
Rated current: 63A or lower
Means of Transport: Ocean,Land,Air
Packing: Neutral or customized
Type: Others
Brand Name: CHKX
Application: modern construction
Criteria: IEC60947-6, GB/T14048.11
Pullution degree: III
Temperature requirment: -5℃- +40℃

adopt mini high breaking capacity circuit breaker, only for power switching between 2 power supplies, can't be used into main power switch,

KXQ1 dual power automatic transfer switch series

◎Application:

This transfer switch mainly consist of micro-computer controller and switch transfer device 2 parts, have special cable to connect them. Switch consist of micro-computer controller , micro electric motor, gear case, micro switch actuator, operation keyboard, LCD, moulded case circuit breaker etc. Have automatic, manual , automatic + manual operation way, mechanism electrical double interlock etc features, maximize to satisfied power supply, power distribution requirement.

 KXQ1 dual power automatic transfer switch series

KXQ1 dual power automatic transfer switch series

◎Model No. and meaning:

 KXQ1 dual power automatic transfer switch series

◎Intelligent controller function

KXQ1 intelligent dual power transfer switch, controller input by keyboard and displayed by LCD, can synchronous detect commonly used power(N) and standby power(R) three phase four wire; have testing function to default phase, overvoltage, undervoltage, lower than 80% of the rated working voltage would be adjudicated as undervoltage, standby power(R) fault alarm, micro computer would have corresponding treatment to the detect result, and send relative order, will display the action result on the LCD, provide a excellent interface between person and apparatus, micro computer tested fault data delay into dual switch off condition, by delay (0-30s) and then transfer to normal power supply.

◎Structure and function:

Switch have 3 working status for use to select: commonly used power(N) on and standby power(R) off, commonly used power(N) off and standby power(R) on, commonly used power(N) off and standby power(R) off. Switch have small volume, light weight, stable performance etc features.

◎Automatic change and automatic recovery(R) electric network

Leave factory initial default automatic, commonly power supply, if power supply fault (any phase loss voltage or loss phase) NA,NB,NC,RA,RB,RC in the controller LCD will disappear relatively. Commonly used power(N) have fault, will transfer to standby power(R) after delay 3s, time delay can be set 0-30s, leave factory default set is 3s.Will transfer from standby power(R) to commonly used power(N) while commonly used power(N) turn to normal; will have "du" "du" alarm voice while standby power(R) have fault. This alarm can be turned off, words "alarm" disappeared in the LCD means turn off alarm system, it would not "alarm" function.

◎Automatic change and automatic recovery(F) electric network

 Controller test commonly used power(N) and generating power (R), control system send generate electricity order(normally open contact) to generator unit to start generator unit while commonly used power(N) have fault, controller send order to put into use electricity power while generator unit voltage reach normal working voltage, to ensure generator unit working normally. Control system automatic break load and into dual switch off status while generator voltage lower than 75% of the rate value. After electric network voltage(N) recover to normal, intelligent system(by time delay) from standby generator power (R) to commonly used power(N) automatically, generator unit should switch off manually.

◎Installation size(universal for both integration type and split type)

 KXQ1 dual power automatic transfer switch series

Model No.

Overall size

Installation size

W*L*H

W1*L1

KXQ1-63/3

380*240*140

350*220

KXQ1-63/4

380*240*140

350*220

KXQ1-100/3

420*240*140

385*220

KXQ1-100/4

420*240*140

385*220

KXQ1-225/3

470*240*150

435*220

KXQ1-225/4

470*240*160

435*220

KXQ1-400/3

615*330*200

555*300

KXQ1-400/4

615*330*200

555*300

KXQ1-630/3

740*330*200

680*300

KXQ1-630/4

740*330*200

680*300

KXQ1-800/3

725*330*210

670*300

KXQ1-800/4

790*330*210

735*300

KXQ1-1250/3

670*390*210

625*370

KXQ1-1250/4

800*390*210

755*370

◎Intelligent dual power controller function explanation

KXQ1 dual power automatic transfer switch series

(AST intelligent controlller)

This controller be used into dual transfer switch, main component adopt selective imported large-scale Harvard architecture micro computer chip, it with stable and reliable performance, less peripheral component, high anti-interference performance, anti-fault operation, anti-crash, anti-unreadable code, anti-loss data, low heating rate, maintenance-free, no regulating element inside, adjustment by software purely. Both hardware and software reach international advantage level.

 Controller input by keyboard and displayed by LCD, can synchronous detect commonly used power(N), standby power(R) three phase four wire; have testing function to default phase, overvoltage. Higher than rated working voltage 265V±5% would be adjudicated as overvoltage, lower than rated working voltage 170V±5% would be adjudicated as undervoltage. Anti-fault operation function is designed for changing suddenly of working power peak. Standby fault alarm(also can be turned off by manual), micro computer would have corresponding treatment to the detect result, and send perform order, will display the action result on the LCD, provide a excellent interface between person and apparatus. Boot initialization default automatic, commonly working mode.

◎Working mode:

Automatic change and automatic recovery(R) type: apply to between electric networks

Automatic change and automatic recovery(F) type: apply to between electric network and generate electricity

Automatic change but without automatic recovery(S) type: apply to between electric networks

◎Automatic change and automatic recovery(R) type: electric network to electric network

Boot initialization default automatic, commonly power supply (can realize manual, dual switch off function simultaneously), while commonly used power(N) have fault(any phase overvoltage, undervoltage or loss phase), will transfer automatically to standby power(R) by time delay, time delay can be set 0-30s, leave factory default set is 3s.Will transfer from standby power(R) to commonly used power(N) automatically while commonly used power(N) turn to normal; controller will send order dual switch off the switches when detected fire fighting order; while alarm system switch on , controller display alarm, will have "du" "du" alarm voice when commonly used/standby power have fault or detected fire fighting order.

◎Automatic change but without automatic recovery(S) type: electric network to electric network

Boot initialization default automatic, commonly power supply (can realize manual, dual switch off function simultaneously), while commonly used power(N) have fault(any phase overvoltage, undervoltage or loss phase), will transfer automatically to standby power(R) by time delay, time delay can be set 0-30s, leave factory default set is 3s. It can't transfer from standby power(R) to commonly used power(N) automatically while commonly used power(N) turn to normal; It can transfer to commonly used power(N) automatically by time delay while standby power(R) have fault (any phase overvoltage, undervoltage or loss phase); controller will send order dual switch off the switches when detected fire fighting order; while alarm system switch on , controller display alarm, will have "du" "du" alarm voice when commonly used/standby power have fault or detected fire fighting order.

◎Automatic change and automatic recovery(F) type: electric network to generate electricity,

Controller test commonly used power(N) and generating power (R), control system send generate electricity order(independent normally open contact) to generator unit to start generator unit while commonly used power(N) have fault, After commonly used power(N) recover to normal, intelligent system(by time delay) turn to commonly used power(N) automatically, generator unit should switch off manually.

Note: Can add fire fighting function for all those three function mode

 KXQ1 dual power automatic transfer switch series

KXQ1 dual power automatic transfer switch series

Harvard architecture high performance low power consumption singlechip

Advantage technique, maintenance-free, long life, no crash, no unreadable code, won't burn out circuit board if phase sequence misconnection(1min) etc features

Have overvoltage, undervoltage, loss phase, fire fighting, generator etc protection function

Intelligent online upgrade, online programming

Moulded case adopt anti-flaming material

Human conversation interface, modern large blue screen (LCD) display 

bigPhoto
skype Ms. RUBY XIA

Tel: 86-531-88626363
Fax: 86-531-88626268
Mobile: 135 1577 0044
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

JINAN STAR ELECTRIC EQUIPMENT CO., LTD [China (Mainland)]


Business Type:Manufacturer, Trading Company, Agent
City: Wenzhou
Province/State: Zhejiang
Country/Region: China (Mainland)

RUBY XIA:   skype
RUBY:   qq

You May Like: